Schneider Electric Acti9 iC60N 2P B 1A MCB

A9F43201https://download.schneider-electric.com/files?p_Doc_Ref=PB111066&p_File_Type=rendition_4000_pngActi9 iC60N 2P 1A B Miniature Circuit breaker. Label: iC60 - [In] rated current: 1 A - network type: AC - trip unit technology: thermal-magnetic - curve code: B - breaking capacity code: N - breaking capacity: N/A, N/A, N/A, N/A, N/A, N/A - range: Acti 9 - utilisation category: category A conforming to EN/IEC 60947-2 - range of product: Acti 9 - product name: Disbo iC60 - product or component type: miniature circuit-breaker - device short name: iC60N - poles description: 2P - number of protected poles: 2 - Range Presentation: With exclusive features, the Acti 9 iC60 DIN rail MCB is definitely geared to absolute safety and improved continuity of service. - VisiSafe : for safe operation and maintenance work on circuits.- Class-2 insulation : continuous safety for operators and unqualified personnel.- VisiTrip : detects faulty Miniature Circuit-Breaker outgoers quickly and reduces intervention time.- Add-on fully immune earth leakage protection devices : better continuity of service, especially in polluted environments and networks.- Nominal current: 1 to 63 A- Large choice of breaking capacities up to 100 kA and tripping curves: B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,- Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs), - Suitable for isolation in accordance with industrial standard IEC 60947- Operating voltage: up to 440 V AC, insulation voltage: 500 V- Optional add-on earth leakage modules: iC60 Vigi, - Optional auxiliaries: indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping, - Range Benefits: - The new reference in final distribution,- Absolute safety of circuit protection with VisiSafe,- Greater continuity of service with VisiTrip,- Simple to choose with meaningful part numbers,- Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),- Environmentally friendly with 100% recyclable & recoverable materials. - Range Application Presentation: Low-voltage final distribution - Protection of electrical circuits in all industrial and commercial buildings,- All applications, especially in polluted environments and networks,- Motor circuit protection,- DC current circuit protection.
GBP
Stock Code: A9F43201
Call for availability on 0345 030 60 80
This item is Obsolete
119999.99£99,999.99 (exc VAT) per 1
£119,999.99 (inc VAT)
Quantity: - +
Acti9 iC60N 2P 1A B Miniature Circuit breaker. Label: iC60 - [In] rated current: 1 A - network type: AC - trip unit technology: thermal-magnetic - curve code: B - breaking capacity code: N - breaking capacity: N/A, N/A, N/A, N/A, N/A, N/A - range: Acti 9 - utilisation category: category A conforming to EN/IEC 60947-2 - range of product: Acti 9 - product name: Disbo iC60 - product or component type: miniature circuit-breaker - device short name: iC60N - poles description: 2P - number of protected poles: 2 - Range Presentation: With exclusive features, the Acti 9 iC60 DIN rail MCB is definitely geared to absolute safety and improved continuity of service.
- VisiSafe : for safe operation and maintenance work on circuits.- Class-2 insulation : continuous safety for operators and unqualified personnel.- VisiTrip : detects faulty Miniature Circuit-Breaker outgoers quickly and reduces intervention time.- Add-on fully immune earth leakage protection devices : better continuity of service, especially in polluted environments and networks.- Nominal current: 1 to 63 A- Large choice of breaking capacities up to 100 kA and tripping curves: B, C, D, Compliance with standards IEC/EN 60898 or IEC/EN 60947-2,- Full coordination with Acti 9 range Residual Current Devices (RCDs) and Compact NSX Moulded Case Circuit Breakers (MCCBs), - Suitable for isolation in accordance with industrial standard IEC 60947- Operating voltage: up to 440 V AC, insulation voltage: 500 V- Optional add-on earth leakage modules: iC60 Vigi, - Optional auxiliaries: indication of state and tripping, shunt tripping, undervoltage tripping, overvoltage tripping,
- Range Benefits:
- The new reference in final distribution,- Absolute safety of circuit protection with VisiSafe,- Greater continuity of service with VisiTrip,- Simple to choose with meaningful part numbers,- Easy to install with quick, ergonomic & safe IP20B terminal shutters & robust connections (twice the standard tightening torque),- Environmentally friendly with 100% recyclable & recoverable materials. - Range Application Presentation: Low-voltage final distribution
- Protection of electrical circuits in all industrial and commercial buildings,- All applications, especially in polluted environments and networks,- Motor circuit protection,- DC current circuit protection.
Width36 mm
Height85 mm
Depth78.5 mm