ATV212WU15N4https://www.cca.co.uk/image.php?filename=atv212wu15n4.jpg&stockcode=ATV212WU15N4&category=hvac-vsd-range-atv21--atv-21w&width=1000&height=1000variable speed drive ATV212 - 1.5kW - 2hp - 480V - 3ph - EMC class C2 - IP55.Label:Altivar 212-range of product:Altivar 212-supply voltage limits:323-528 V-network frequency:47.5...63 Hz-EMC filter:Class C2 EMC filter integrated-product or component type:variable speed drive-device short name:ATV212-product destination:asynchronous motors-product specific application:pumps and fans in HVAC-assembly style:with heat sink-network number of phases:3 phases-Range Presentation:The Altivar 212 is a variable speed drive for 3-phase asynchronous motors from 0.75 kW to 75 kW. It is specifically intended for the most commonly encountered fluid management applications in tertiary sector buildings (HVAC): heating, ventilation, air conditioning and pumping. Due to its eco-energy based design, energy savings of up to 70% can be achieved compared to a traditional control system.Characteristics:
- Altivar 212 covers motor powers between 0.75 kW and 75 kW on the following supplies:
- 200...240V 3-phase, from 0.75 kW to 30 kW, IP 21 - 380...480V 3-phase, from 0.75 kW to 75 kW, IP 21 - 380...480V 3-phase, from 0.75 kW to 75 kW, UL Type 12/IP 55- Speed range: 1:50 - Transient over torque: 110% - 60 s. - Integrated EMC filters, categories C1 to C3 depending on model - Communication bus most commonly used on the market integrated: Modbus, METASYS N2®, APOGEE FLN P1® and BACnet®. Optional: LonWorks - Complies to international standards and certifications: UL, CSA, C-Tick and NOM - Antiharmonic technology enables a THDI 30% to be achievedVentilation:
- Less noise pollution (airdraulic noise, motor noise, etc.). - Detection of transmission component breakage. - Smoke extraction: forced start with fault inhibition. - Automatic restart. - Allows register management. Heating and Air conditioning:
- Optimise control in fluid processing. - Use of PID controller (temperature, flow rate, pressure, etc.). - Adjustable flow rates for better energy management. - Suppression of mechanical resonance.Pumping:
- Detection of underload/overload, pump running dry. - Multi-motor configuration. - Limitation of operating time at low speed. - Sleep/Wake function. - Pressure surge suppression for prolonging the life of the installation.-Range Benefits:Centred on Centralised Technical Management
- Instant viewing of the energy consumption. - Detection of failures for quick intervention: belt breakage, pump running dry, phase failure, supply fault, etc. - Preventative maintenance for reducing costs and optimising the equipment: fault alert, operating time, etc. - Connection to building supervision network using embedded protocols.Centred on user-friendliness
- Tools for installing, parametering and viewing the installation (remote graphic terminal in 6 languages, Multi-Loader, Bluetooth and SoMove Mobile). - Compact size. - Simple maintenance.Centred on protection
- Continuity of service assured. - Dedicated "Building" series functions (fire mode, register monitoring, mechanical protection function, etc. - Integrated EMC filter, anti harmonic technology (THDI ~ 30%).-Range Application Presentation:Ventilation:
- Less noise pollution (airdraulic noise, motor noise, etc.)
- Detection of transmission component breakage
- Smoke extraction: forced start with fault inhibition
- Automatic restart
- Allows register management
Heating and Air conditioning:
- Optimise control in fluid processing
- Use of PID controller (temperature, flow rate, pressure, etc.)
- Adjustable flow rates for better energy management
- Suppression of mechanical resonance
Pumping:
- Detection of underload/overload, pump running dry
- Multi-motor configuration
- Limitation of operating time at low speed
- Sleep/Wake function
- Pressure surge suppression for prolonging the life of the installation
GBP
Stock Code: ATV212WU15N4
Call for availability on 0345 030 60 80
915.17£762.64 (exc VAT) per 1
£915.17 (inc VAT)
Quantity: - +
variable speed drive ATV212 - 1.5kW - 2hp - 480V - 3ph - EMC class C2 - IP55.Label:Altivar 212-range of product:Altivar 212-supply voltage limits:323-528 V-network frequency:47.5...63 Hz-EMC filter:Class C2 EMC filter integrated-product or component type:variable speed drive-device short name:ATV212-product destination:asynchronous motors-product specific application:pumps and fans in HVAC-assembly style:with heat sink-network number of phases:3 phases-Range Presentation:The Altivar 212 is a variable speed drive for 3-phase asynchronous motors from 0.75 kW to 75 kW. It is specifically intended for the most commonly encountered fluid management applications in tertiary sector buildings (HVAC): heating, ventilation, air conditioning and pumping. Due to its eco-energy based design, energy savings of up to 70% can be achieved compared to a traditional control system.Characteristics:
- Altivar 212 covers motor powers between 0.75 kW and 75 kW on the following supplies:
- 200...240V 3-phase, from 0.75 kW to 30 kW, IP 21 - 380...480V 3-phase, from 0.75 kW to 75 kW, IP 21 - 380...480V 3-phase, from 0.75 kW to 75 kW, UL Type 12/IP 55- Speed range: 1:50 - Transient over torque: 110% - 60 s. - Integrated EMC filters, categories C1 to C3 depending on model - Communication bus most commonly used on the market integrated: Modbus, METASYS N2®, APOGEE FLN P1® and BACnet®. Optional: LonWorks - Complies to international standards and certifications: UL, CSA, C-Tick and NOM - Antiharmonic technology enables a THDI 30% to be achievedVentilation:
- Less noise pollution (airdraulic noise, motor noise, etc.). - Detection of transmission component breakage. - Smoke extraction: forced start with fault inhibition. - Automatic restart. - Allows register management. Heating and Air conditioning:
- Optimise control in fluid processing. - Use of PID controller (temperature, flow rate, pressure, etc.). - Adjustable flow rates for better energy management. - Suppression of mechanical resonance.Pumping:
- Detection of underload/overload, pump running dry. - Multi-motor configuration. - Limitation of operating time at low speed. - Sleep/Wake function. - Pressure surge suppression for prolonging the life of the installation.-Range Benefits:Centred on Centralised Technical Management
- Instant viewing of the energy consumption. - Detection of failures for quick intervention: belt breakage, pump running dry, phase failure, supply fault, etc. - Preventative maintenance for reducing costs and optimising the equipment: fault alert, operating time, etc. - Connection to building supervision network using embedded protocols.Centred on user-friendliness
- Tools for installing, parametering and viewing the installation (remote graphic terminal in 6 languages, Multi-Loader, Bluetooth and SoMove Mobile). - Compact size. - Simple maintenance.Centred on protection
- Continuity of service assured. - Dedicated "Building" series functions (fire mode, register monitoring, mechanical protection function, etc. - Integrated EMC filter, anti harmonic technology (THDI ~ 30%).-Range Application Presentation:Ventilation:
- Less noise pollution (airdraulic noise, motor noise, etc.)
- Detection of transmission component breakage
- Smoke extraction: forced start with fault inhibition
- Automatic restart
- Allows register management
Heating and Air conditioning:
- Optimise control in fluid processing
- Use of PID controller (temperature, flow rate, pressure, etc.)
- Adjustable flow rates for better energy management
- Suppression of mechanical resonance
Pumping:
- Detection of underload/overload, pump running dry
- Multi-motor configuration
- Limitation of operating time at low speed
- Sleep/Wake function
- Pressure surge suppression for prolonging the life of the installation
Weight6.855 kg